TECOL510Inverter
QuickStartGuide
Thisguideistoassistyouininstallingandrunningtheinverterandverifythatitis
functioningcorrectlyforit’smainandbasicfeatures.
Fordetailedinformationandifthereareanydoubtspleaserefertotheinstructionmanual.
Step1SupplyMotorconnection
1)EnsurethattheInverterthemotorhavethecorrect
KWpowerandvoltageratings.
MotorfullloadampsmustnotexceedtheInverterrating.
2)EnsurethatthesupplyMotorcablesareconnected
correctlypriortopowerup.
3)Forsinglephasesupply,useL1(L)L3(N)onunitswhich
have3supplyterminals.
4)ConnectmotorcabletoterminalsT1,T2T3.
(Swaptwoleadsifmotorrunsinreversedirection).
Note:-
5)ConnectsupplyEarthandthemotorEarthtothedriveEarth
I)Fordetailedinstallation
terminal.
andwiringrefertothe
Instructionmanual.
Page1of708/08/14
Step2Applypowertothedrive
Applypowertothedrive,thedisplaywillbrieflyshowthesupplyvoltage
220Vfollowedby5.00flashing.
Thisisthedefault(factoryset)frequency.
Iftheunithasbeenusedpreviouslythenitwillshowthelastfrequency
programmed.
Note:-50HZissetasmaximumdefaultfrequency.ThisProvidesmotorfullspeed.
Step3Testrunfromkeypad
PressRUNKEYtorun.
Thefrequencywillrampupto5.0Hzortheuserpre-setfrequencyand
accordingtothedefaultaccelerationrampt