NOTESfortheSDU5000(Rev1.3)

1.FirstensurethatthereceiverisswitchedOnandconnectedtotheSDU5000.TheSDUROMwill

permitoperationwiththeAORAR3000A,ICOMIC-R7000,IC-R7100,IC-R9000andasabandscope

withotherreceiverswitha10.7MHzI.F.outputsuchastheAORAR3000(asmallmodificationis

requiredtotheAORreceiversinordertoprovidecompatibility).

IfusinganICOMreceiver,theCT17optionalinterfacewillberequired.TheICOMreceivermustbe

configuredforremotecontrol,refertotheICOMoperatingmanual.Thefollowingsetupisrequired:

Baudrate9600bps

Frequencydata5Byte

TransceiveON

Addressdefault

IC-R700008H

IC-R710034H

IC-R90002AH

ExamplesetupfortheICOMIC-R7100receiver

Step1.FortransceiveON

OntheICOMreceiver,pressandholdboth3andENTkeysandswitchthepowerswitchON.

ThenswitchthereceiverOFF.

Step2.Forbaudrateof9600

OntheICOMreceiver,pressandholdboththe5andENTkeysandswitchthepowerswitchON.

ThenswitchthereceiverOFF.

ThereceivermustbeconfiguredandswitchedOnbeforetheSDU5000inordertoguaranteeavalid

connectionviatheRS232.

Note:TheoutputleveloftheICOMreceiver(s)isabout10-15dBbelowthatoftheAORreceiver(s).

2.Shouldtheconnectionbelost,use“CONF”toconfirmthatthecorrectreceiverhadbeenselected.

3.Ifaconnectioncannotbeestablished,switchOfftheSDU5000,unplugthe12VDCfeedandleave

theunitfor10seconds.Reconnectandtryagain.

4.Itispossibletogetfalseindicationsbelow0MHz!!(minusfigureswillappearinfrontofthe

frequencyreadout).

5.Asmal