斜面辐照量/(kWh/㎡) 0 100.00% 计算系数 单面发电量/MWh 单面发电量/万kWh 单面等效满发小时数/h 双面增益 双面发电量/MWh 双面发电量/万kWh 双面等效满发小时数/h
2010 1 99.00% 99.50% 81997.95 8199.80 1639.96 0.0% 81997.95 8199.8 1640.0
2 98.60% 98.80% 81421.08 8142.11 1628.42 81421.08 8142.1 1628.4
系统首年PR值 3 98.20% 98.40% 81091.44 8109.14 1621.83 81091.44 8109.1 1621.8
82.0% 4 97.80% 98.00% 80761.80 8076.18 1615.24 80761.80 8076.2 1615.2
5 97.40% 97.60% 80432.16 8043.22 1608.64 80432.16 8043.2 1608.6
第0年理论发电小时数 6 97.00% 97.20% 80102.52 8010.25 1602.05 80102.52 8010.3 1602.1
1648.20 7 96.60% 96.80% 79772.88 7977.29 1595.46 79772.88 7977.3 1595.5
8 96.20% 96.40% 79443.24 7944.32 1588.86 79443.24 7944.3 1588.9
系统装机容量/MWp 9 95.80% 96.00% 79113.60 7911.36 1582.27 79113.60 7911.4 1582.3
50 10 95.40% 95.60% 78783.96 7878.40 1575.68 78783.96 7878.4 1575.7
11 95.00% 95.20% 78454.32 7845.43 1569.09 78454.32 7845.4 1569.1
首年衰减 12 94.60% 94.80% 78124.68 7812.47 1562.49 78124.68 7812.5 1562.5
1.00% 13 94.20% 94.40% 77795.04 7779.50 1555.90 77795.04 7779.5 1555.9
14 93.80% 94.00% 77465.40 7746.54 1549.31 77465.40 7746.5 1549.3
逐年衰减 15 93.40% 93.60% 77135.76 7713.58 1542.72 77135.76 7713.6 1542.7
0.40% 16 93.00% 93.20% 76806.12 7680.61 1536.12 76806.12 7680.6 1536.1
17 92.60% 92.80% 76476.48 7647.65 1529.53 76476.48 7647.6 1529.5
18 92.20% 92.40% 76146.84 7614.68 1522.94 76146.84 7614.7 1522.9
19 91.80% 92.00% 75817.20 7581.72 1516.34 75817.20 7581.7 1516.3
20 91.40% 91.60% 75487.56 7548.76 1509.75 75487.56 7548.8 1509.8
21 91.00% 91.20% 75157.92 7515.79 1503.16 75157.92 7515.8 1503.2
22 90.60% 90.80% 74828.28 7482.83 1496.57 74828.28 7482.8 1496.6
23 90.20% 90.40% 74498.64 7449.86 1489.97 74498.64 7449.9 1490.0
24 89.80% 90.00% 74169.00 7416.90 1483.38 74169.00 7416.9 1483.4
25 89.40% 89