经验点滴|ExperiencesDOI:10.13882/ki.ncdqh.2024.06.023
一起窃电引起台区负线损率的案例分析
*
汪岳荣,吴佳雨
(国网浙江衢州供电公司,浙江衢州324002)
摘要:
台区线损治理是供电企业一项长期的重要工作,台区高线损率和负线损率是台区线损治理过程中
较为常见的问题。在台区线损治理工作中,用户窃电是引起线损率升高的重要原因之一,也是较为常见
的现象,但窃电引起台区负线损率的问题较为少见,也容易被忽视,现结合实际案例进行分析。
关键词:
窃电;台区负线损率;案例分析中图分类号:
TM714.3
Case
Analysis
of
Negative
Line
Loss
Rate
in
Substation
Area
Caused
by
Electricity
Stealing
*
WANG
Yuerong,
WU
Jiayu
(State
Grid
Zhejiang
Quzhou
Power
Supply
Company,
Zhejiang
Quzhou
324002,
China)
Abstract:
Power
substation
areas
line
loss
management
is
a
long-term
important
task
for
power
supply
enterprises.
High
line
loss
rate
and
negative
line
loss
rate
are
common
problems
in
the
process
of
line
loss
management.
In
the
actual
work
of
line
loss
control
in
substation
area,
electricity
stealing
is
one
of
the
important
reasons
for
the
increase
of
line
loss
rate,
which
is
also
a
relatively
common
phenomenon.
but
the
problem
of
negative
line
loss
rate
caused
by
electricity
stealing
is
relatively
rare,
and
is
easy
to
be
ignored.
This
paper
analyzes
an
actual
case
which
causes
negative
line
loss
rate
in
substation
area.
Keywords:
electricity
stealing;
negative
line
loss
in
substation
area;
case
analysis
1问题背景2跟踪排查